{"product_id":"330102-08-15-10-02-00-bently-nevada-3300-xl-8mm-proximity-probe","title":"330102-08-15-10-02-00 Bently Nevada 3300 XL 8mm Proximity Probe","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330102-08-15-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a precision cornerstone for non-contact displacement and vibration monitoring in high-criticality industrial assets. This 3300 XL 8mm proximity probe specifically targets metric-threaded installations, capturing microscopic shaft movements in steam turbines, centrifugal compressors, and large-scale motors. By utilizing advanced eddy current technology, the sensor delivers accurate radial vibration and axial position data without physical interaction, ensuring zero mechanical wear and long-term signal stability.\u003c\/p\u003e\n\u003cp\u003eAs a primary sensing element for Turbine Supervisory Instrumentation (TSI), this probe identifies early mechanical instabilities such as shaft unbalance, misalignment, or bearing degradation. It produces a high-fidelity voltage signal proportional to the gap between the probe tip and the target surface, allowing plant operators to implement sophisticated predictive maintenance. Its ruggedized design ensures consistent performance in the punishing environments typical of oil, gas, and power generation sectors.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Configuration (Metric Thread)\u003c\/h2\u003e\n\u003cp\u003eThe model\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330102-08-15-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes a metric (M10 x 1) thread pattern, distinguishing it from standard fractional models. Each segment of the part number dictates the mechanical fit and electrical compatibility:\u003c\/p\u003e\n\u003ch3\u003eUnthreaded Length Option (-08)\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e08\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eindicates an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e80 mm\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunthreaded length. This configuration allows the probe to pass through thick mounting brackets or machine casings while maintaining a specific penetration depth toward the target shaft.\u003c\/p\u003e\n\u003ch3\u003eOverall Case Length Option (-15)\u003c\/h3\u003e\n\u003cp\u003eThis designates a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e150 mm\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoverall case length. The M10 x 1 threaded housing provides a secure mechanical anchor, ensuring the probe remains stable under high-vibration conditions.\u003c\/p\u003e\n\u003ch3\u003eTotal Length Option (-10)\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003especifies a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1.0-meter (approx. 3.3 feet)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etotal probe lead length. In the 3300 XL ecosystem, the probe lead must match the calibrated total system length (typically 5.0m or 9.0m when paired with an extension cable) to maintain the precise 200 mV\/mil scale factor.\u003c\/p\u003e\n\u003ch3\u003eConnector and Agency Option (-02-00)\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoption provides a miniature coaxial ClickLoc connector with a connector protector to prevent fluid contamination. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econfirms standard global agency approvals, certifying the unit for safe operation in general industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.0 mm (0.315 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Sensitivity (ISF)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM10 x 1 (Metric)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 °C to +177 °C (-60 °F to +351 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTarget Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 4140 Steel (Standard Calibration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSealing up to 70 psi (4.8 bar)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 Meter (Probe only)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation \u0026amp; Engineering Guide\u003c\/h2\u003e\n\u003cp\u003eSuccessful machinery protection depends on precise gapping and meticulous cable management:\u003c\/p\u003e\n\u003ch3\u003eGap Voltage Calibration\u003c\/h3\u003e\n\u003cp\u003eEngineers must set the initial \"Static Gap\" using a Digital Multimeter (DMM). For a 3300 XL 8mm system, the center of the linear range corresponds to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-10.0 VDC\u003c\/strong\u003e. Rotate the probe within its metric mounting until the Proximitor output reaches this value while the shaft remains at its rest position before tightening the locknuts.\u003c\/p\u003e\n\u003ch3\u003eCable Protection and Routing\u003c\/h3\u003e\n\u003cp\u003eCoaxial leads are sensitive to physical deformation. Maintain a minimum bend radius of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e25.4 mm (1.0 inch)\u003c\/strong\u003e. Protect the cable using flexible conduit to prevent mechanical damage and avoid running probe leads parallel to high-voltage AC lines to prevent electromagnetic interference (EMI) from corrupting the vibration signal.\u003c\/p\u003e\n\u003ch3\u003eSurface Runout Inspection\u003c\/h3\u003e\n\u003cp\u003eThe sensor interprets surface imperfections—such as scratches, rust, or magnetic inclusions—as actual vibration. Ensure the target area on the shaft has a smooth surface finish (typically 0.4 to 0.8 micrometers) to minimize electrical and mechanical runout.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMetric Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe M10 x 1 threading ensures a perfect fit for European and Asian machinery designs without the need for thread adapters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior PPS Tip Construction:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe probe tip utilizes Polyphenylene Sulfide (PPS), a high-performance thermoplastic that resists chemical corrosion and maintains structural integrity across extreme temperature cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAPI 670 Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 3300 XL series meets or exceeds the American Petroleum Institute (API) 670 standards for machinery protection systems, ensuring global interoperability and safety.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGold-Plated ClickLoc Connectors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGold-plated contacts ensure a low-resistance connection and prevent oxidation, a critical feature for high-humidity environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How do I verify the health of the 330102 probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: Measure the DC resistance between the center pin and the outer shield of the coaxial connector. A healthy 1.0m probe lead typically reads between\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5.0 Ω and 9.0 Ω\u003c\/strong\u003e. An infinite reading indicates an open circuit, requiring probe replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Does this probe require an Ethernet router for communication?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: No. This is a common error found in logistics databases. The 330102 is a passive analog eddy-current sensor. It provides a raw signal to a Proximitor Sensor. Digital network communication only occurs at the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500 Monitoring Rack\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elevel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can I use this 1.0m probe with a standard 5.0m system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Yes, provided you pair it with a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4.0-meter extension cable\u003c\/strong\u003e. The total electrical length (Probe + Cable) must equal the calibration of the Proximitor (e.g., 5.0m total) to maintain the correct 200 mV\/mil sensitivity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Is the 330102 compatible with older non-XL 3300 series?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: Yes. The 3300 XL series maintains backward compatibility with legacy 3300 series 8mm components. However, for maximum accuracy and EMI protection, we recommend using a complete 3300 XL transducer system.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53296614342966,"sku":"330102-08-15-10-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2094\/8534\/files\/bently-nevada-330102-08-15-10-02-00-3300-xl-8mm-proximitor-probe-d00hvp2pozi.jpg?v=1764045120","url":"https:\/\/www.motrolixtech.com\/products\/330102-08-15-10-02-00-bently-nevada-3300-xl-8mm-proximity-probe","provider":"Motrolix","version":"1.0","type":"link"}