{"product_id":"330130-040-12-05-bently-nevada-3300-xl-standard-extension-cable","title":"330130-040-12-05 Bently Nevada 3300 XL Standard Extension Cable","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330130-040-12-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the vital high-fidelity link within the 3300 XL Proximity Transducer System. This 4.0-meter extension cable bridges the gap between the proximity probe and the Proximitor sensor, ensuring the seamless transmission of critical displacement and vibration data from high-speed rotating assets. Designed for the unforgiving environments of steam turbines, centrifugal compressors, and electric motors, this cable maintains signal integrity despite extreme temperatures and industrial interference.\u003c\/p\u003e\n\u003cp\u003eBy utilizing gold-plated ClickLoc connectors and advanced shielding, the 330130-040-12-05 facilitates non-contacting measurements with sub-micron precision. It enables real-time monitoring of radial vibration and axial thrust, providing the foundational data required for Turbine Supervisory Instrumentation (TSI) systems to trigger protective shutdowns before catastrophic mechanical failure occurs.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cp\u003eThe model number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330130-040-12-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efollows a specific logic that defines the cable's physical and safety characteristics:\u003c\/p\u003e\n\u003ch3\u003eCable Length (040)\u003c\/h3\u003e\n\u003cp\u003eThe \"040\" designates a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4.0 meter (13.1 feet)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecable length. When combined with a 1.0-meter probe, it creates a standard 5-meter system, calibrated to provide a linear output of 7.87 V\/mm (200 mV\/mil).\u003c\/p\u003e\n\u003ch3\u003eConnector and Cable Option (12)\u003c\/h3\u003e\n\u003cp\u003eThe \"12\" suffix indicates the inclusion of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConnector Protectors\u003c\/strong\u003e. These specialized sleeves shield the miniature coaxial connections from moisture, dust, and corrosive vapors, preventing signal degradation over years of continuous operation.\u003c\/p\u003e\n\u003ch3\u003eAgency Approval Option (05)\u003c\/h3\u003e\n\u003cp\u003eThe \"05\" code signifies\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMultiple Approvals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(including ATEX, IECEx, and CSA). This certification confirms the cable's compliance with global safety standards for installation in hazardous areas where explosive gases or dust may be present.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada 3300 XL (8mm \u0026amp; 5mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.0 Meters (13.1 Feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGold-plated Brass \/ Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePull Strength\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330 N (75 lbf) maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.4 mm (1.0 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 °C to +177 °C (-60 °F to +351 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP66 (when properly installed with protectors)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003cp\u003eCorrect installation of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330130-040-12-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprevents \"noisy\" signals and premature failure. Field engineers should adhere to the following standards:\u003c\/p\u003e\n\u003ch3\u003eConnection Security and Protection\u003c\/h3\u003e\n\u003cp\u003eThe ClickLoc connectors require a positive engagement. Ensure you feel the \"click\" when mating the extension cable to the probe. Slide the integrated connector protectors over the junction to seal out contaminants. If the environment involves constant exposure to turbine oil, replace the standard silicone tape with fluorosilicone heat-shrink tubing for superior chemical resistance.\u003c\/p\u003e\n\u003ch3\u003eRouting and Bend Radius\u003c\/h3\u003e\n\u003cp\u003eNever exceed the minimum bend radius of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e25.4 mm\u003c\/strong\u003e. Sharp kinks in the coaxial line change the cable's capacitance, which directly alters the sensor's calibration and accuracy. Use stainless steel conduit or flexible \"liquid-tight\" housing when routing cables across machine casings to prevent mechanical pinching or abrasion.\u003c\/p\u003e\n\u003ch3\u003eSystem Matching\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL system is length-dependent. Ensure the total length of the probe plus the extension cable matches the Proximitor sensor's calibration (typically 5.0m or 9.0m). Mixing a 4.0m extension cable with a probe that results in a non-standard total length will cause significant scale factor errors.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 XL Extension Cable\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes the patented\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCableLoc\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesign, providing a robust 330N pull strength. This mechanical reinforcement prevents the coaxial core from separating from the connector during routine maintenance or high-vibration events.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the gold-plated contacts eliminate the risk of fretting corrosion, a common cause of intermittent signals in older transducer systems. Its wide temperature range and resistance to corrosive lubricants make it the global standard for heavy industrial machinery protection, ensuring seamless compatibility with 3500 and 3701 monitoring racks.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can I use this 4.0m extension cable with a legacy 7200 series probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: No. The 3300 XL series and the 7200 series have different electrical characteristics and connector designs. Mixing these generations will lead to inaccurate readings and potential system errors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How do I know if I need the \"FluidLoc\" option instead of this standard cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: You should choose FluidLoc if the cable must pass through a bulkhead where oil or gas pressure exists on one side. The 330130-040-12-05 is a standard cable; while it resists surface oil, it is not designed to act as a pressure-tight seal against internal fluid migration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What should I do if the connector gets submerged in oil during installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Clean the connector immediately with an approved electronic contact cleaner that leaves no residue. Ensure the connector is completely dry before mating, as trapped moisture or oil can cause signal \"drifting\" in the Gap Voltage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Is the total system length (5m vs 9m) critical for the 330130 cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: Absolutely. The Proximitor sensor is calibrated to a specific electrical length. If you use a 4.0m cable (total 5m system) on a Proximitor designed for 9m, your vibration data will be mathematically incorrect. Always verify the Proximitor label before installation.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53296614080822,"sku":"330130-040-12-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2094\/8534\/files\/bently-nevada-330130-040-12-05-extension-cable-3osretu2yb1.jpg?v=1764045110","url":"https:\/\/www.motrolixtech.com\/products\/330130-040-12-05-bently-nevada-3300-xl-standard-extension-cable","provider":"Motrolix","version":"1.0","type":"link"}