{"product_id":"330904-00-140-05-02-00-bently-nevada-3300-nsv-proximity-probe","title":"330904-00-140-05-02-00 Bently Nevada 3300 NSv Proximity Probe","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330904-00-140-05-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebelongs to the specialized\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 NSv (Narrow System vent)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eproximity transducer line. This high-precision eddy current sensor captures vibration and position data in environments where standard 8mm probes simply cannot fit. It excels in monitoring high-speed centrifugal compressors, small-diameter pumps, and auxiliary turbines where target sizes are limited or radial clearances are extremely tight.\u003c\/p\u003e\n\u003cp\u003eUnlike standard proximity systems, the NSv probe maintains high-fidelity signal output on targets as small as 5mm (0.2 in). By providing non-contact displacement measurements, this probe identifies microscopic shaft instabilities—such as unbalance, misalignment, or bearing wear—without physical interaction. This real-time data flow serves as a critical pillar for Turbine Supervisory Instrumentation (TSI), allowing maintenance teams to implement predictive strategies that prevent catastrophic failures and optimize machinery uptime in the most demanding oil, gas, and power generation facilities.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330904-00-140-05-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodel utilizes a modular part-numbering system to define its mechanical and electrical specifications for field compatibility:\u003c\/p\u003e\n\u003ch3\u003eUnthreaded Length Option (-00)\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eindicates a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.0-inch\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunthreaded length. This configuration provides a fully threaded body (3\/8-24 UNF), allowing maximum flexibility when mounting the probe through thick brackets or machine casings.\u003c\/p\u003e\n\u003ch3\u003eOverall Case Length Option (-140)\u003c\/h3\u003e\n\u003cp\u003eThis designates an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e14.0-inch\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoverall case length. The extended housing allows the probe tip to reach deeply recessed shaft targets while keeping the cable exit safely outside the high-vibration or high-heat zone.\u003c\/p\u003e\n\u003ch3\u003eTotal Length Option (-05)\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003especifies a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.5-meter (approx. 1.6 feet)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etotal system length. Because NSv systems are highly sensitive to cable impedance, the probe lead must match the calibrated length of the 3300 NSv Proximitor to ensure a linear 200 mV\/mil scale factor.\u003c\/p\u003e\n\u003ch3\u003eConnector and Agency Option (-02-00)\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoption includes a miniature coaxial ClickLoc connector with a connector protector to prevent fluid ingress. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econfirms standard global agency approvals, certifying the unit for safe operation in hazardous industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.0 mm (0.197 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8-24 UNF-2A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 mm (60 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Sensitivity (ISF)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLinearity Error\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLess than ±5% of ideal straight line\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 °C to +177 °C (-60 °F to +351 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal System Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 Meter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSealing up to 70 psi (4.8 bar)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation \u0026amp; Engineering Guide\u003c\/h2\u003e\n\u003cp\u003eReliable machinery protection starts with precise sensor gapping and meticulous cable management:\u003c\/p\u003e\n\u003ch3\u003eGap Voltage Calibration\u003c\/h3\u003e\n\u003cp\u003eInstallers must set the initial gap using a Digital Multimeter (DMM). For the 3300 NSv system, the center of the linear range corresponds to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-10.0 VDC\u003c\/strong\u003e. Rotate the probe until the Proximitor output reaches this value while the shaft is at its rest position before tightening the locknuts.\u003c\/p\u003e\n\u003ch3\u003eMinimum Side Clearance\u003c\/h3\u003e\n\u003cp\u003eThe NSv probe requires less side-view clearance than standard probes, but it is not immune to \"side-loading.\" Maintain a minimum of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e6.4 mm (0.25 in)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof radial clearance from any surrounding metal other than the target surface to prevent signal distortion and false readings.\u003c\/p\u003e\n\u003ch3\u003eConnector Integrity\u003c\/h3\u003e\n\u003cp\u003eAlways utilize the provided connector protectors. Moisture or oil ingress into the coaxial connection remains the leading cause of \"signal drift.\" Ensure the ClickLoc connectors are finger-tight and dry before sliding the protector sleeve over the junction. Maintain a minimum cable bend radius of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e25.4 mm (1.0 inch)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSmall Target Optimization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 5mm tip geometry prevents \"averaging\" errors on small-diameter shafts, providing accurate 200 mV\/mil sensitivity where 8mm probes fail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTSI Seamless Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis probe interfaces directly with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3500 series\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emonitoring racks, ensuring data flows instantly into System 1 software for comprehensive diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHermetic Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe PPS (Polyphenylene Sulfide) tip and stainless steel body are vacuum-sealed, protecting the internal sensing coil from caustic industrial fluids and extreme thermal cycling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEMI\/RFI Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAdvanced shielding prevents electrical noise from Variable Frequency Drives (VFDs) and high-voltage motor starters from corrupting the delicate vibration signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How does the NSv system differ from the standard 3300 XL 8mm system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: The NSv (Narrow System vent) is specifically designed for small targets (down to 5mm diameter) and tight spaces. It uses a 5mm tip and has a shorter linear range (60 mils) compared to the 80-mil range of the standard 8mm probe.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can I use this 0.5m probe with a 5.0m extension cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: No. This probe is calibrated for a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.5-meter total system length\u003c\/strong\u003e. It must connect directly to a 0.5m NSv Proximitor. Adding an extension cable will alter the system impedance and result in significant measurement errors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does this probe connect to an Ethernet router?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: No. This is a common database error. The 330904 is a passive analog sensor. It provides a raw signal to a Proximitor Sensor, which then interfaces with a 3500 Rack. Network communication only occurs at the monitor\/rack level.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What is the benefit of the -140 Case Length option?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: The 14-inch extended case length allows the probe to reach internal shafts in machines with thick outer casings or double-wall designs, ensuring the probe tip is positioned correctly without needing complex internal brackets.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53296614703414,"sku":"330904-00-140-05-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2094\/8534\/files\/bently-nevada-330904-00-140-05-02-00-3300-nsv-proximity-probes-3mj31lg3lhh.jpg?v=1764045132","url":"https:\/\/www.motrolixtech.com\/products\/330904-00-140-05-02-00-bently-nevada-3300-nsv-proximity-probe","provider":"Motrolix","version":"1.0","type":"link"}