{"product_id":"bently-nevada-3500-22m-288055-01-standard-transient-data-interface-module","title":"Bently Nevada 3500\/22M 288055-01 Transient Data Interface Module","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3500\/22M 288055-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary communication gateway between the Bently Nevada 3500 Monitoring System and compatible software (System 1 Condition Monitoring and Diagnostic software). As the \"intelligence hub\" of the rack, the 3500\/22M (Transient Data Interface or TDI) collects static and dynamic (transient) waveform data from the monitoring modules, allowing for sophisticated vibration analysis and machinery diagnostics. It bridges the gap between basic machinery protection and advanced predictive maintenance by capturing critical data during machine startups, shutdowns, and alarm events.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 288055-01 is the standard Ethernet-compatible TDI designed for high-speed data transmission and seamless rack integration.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.0 Watts typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFront Panel Connections\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10\/100 Base-T RJ45 Ethernet Port, RS232 Configuration Port\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Module Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10\/100 Base-T Ethernet I\/O Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Types Supported\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStatic, Transient, Dynamic (Waveform)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30°C to +65°C (-22°F to +150°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInternal Storage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNon-volatile memory for configuration and event logs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOK, TX\/RX (Transmit\/Receive), TM (Test Mode), CONFIG\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eModel Code Decomposition\u003c\/h3\u003e\n\u003cp\u003eThe part number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/22-01-01-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(utilizing the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e288055-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emain board) breaks down as follows to define the specific hardware configuration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e3500\/22M:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe base model designation for the Enhanced Transient Data Interface. The \"M\" denotes enhanced capabilities over the original 3500\/22.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01 (Option 1):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifies the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eStandard I\/O Module\u003c\/strong\u003e. This determines the physical interface at the rear of the rack, typically utilizing the 10\/100 Base-T Ethernet connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01 (Option 2):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndicates\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEthernet (10\/100 Base-T) Connectivity\u003c\/strong\u003e. This is the modern standard for high-bandwidth data offloading to System 1.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02 (Option 3):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDefines the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAgency Approval Option\u003c\/strong\u003e. Specifically, this often denotes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMulti-Agency Approvals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(ATEX\/IECEx\/CSA) for use in Class I, Division 2 or Zone 2 hazardous areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e288055-01:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis is the specific manufacturing part number for the main TDI circuit board assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation and Wiring Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo ensure optimal performance and prevent data corruption, follow these installation standards:\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSlot Placement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 3500\/22M TDI must be installed in the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efirst slot\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(leftmost side, immediately next to the Power Supplies) of the 3500 rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Module Alignment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the rear I\/O module (Ethernet\/RS232) is perfectly aligned with the front-facing TDI processor. Misalignment during \"hot-swapping\" can damage the backplane connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe rack must be properly grounded to the plant's instrumentation earth. Use shielded Cat5e or Cat6 cables for Ethernet connections to minimize EMI\/RFI interference from heavy machinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnect via the front RS232 port using the 3500 Rack Configuration Software to assign an IP address before connecting to the plant network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ: Frequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I upgrade my old 3500\/22 to the 3500\/22M 288055-01?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The 3500\/22M is backward compatible with 3500 racks; however, it requires Rack Configuration Software version 4.0 or later and may require a firmware update of other modules in the rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module support \"Hot Swapping\"?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, the 3500\/22M is designed to be removed or installed while the rack is powered. Note that machinery protection remains active, but data communication to System 1 will be interrupted during the swap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary difference between the 3500\/22M and the 3500\/25?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 3500\/22M (TDI) is the communication gateway for the\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eentire rack\u003c\/em\u003e, whereas the 3500\/25 is a Keyphasor module used specifically for providing timing signals to the other modules.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53296692265270,"sku":"288055-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2094\/8534\/files\/bently-nevada-3500-22m-288055-01-standard-transient-data-interface-module-hzciwin5lcs.jpg?v=1764049180","url":"https:\/\/www.motrolixtech.com\/products\/bently-nevada-3500-22m-288055-01-standard-transient-data-interface-module","provider":"Motrolix","version":"1.0","type":"link"}