Overview
The Bently Nevada 177230-01-01-05 Seismic Transmitter delivers high-precision vibration detection for industrial machinery. It is engineered to monitor even subtle vibrations in critical equipment, enabling early fault detection and preventing unexpected downtime. Ideal for turbines, motors, compressors, and pumps, this transmitter integrates seamlessly into condition monitoring systems to provide reliable, real-time data.
Technical Specifications
| Parameter |
Specification |
| Brand |
Bently Nevada |
| Product Series |
Seismic Transmitter |
| Model Number |
177230-01-01-05 |
| Module Type |
Vibration / Seismic Transmitter |
| Output Signal |
4–20 mA |
| Protection |
IP65 |
| Operating Temperature |
-40°C to 85°C |
| Power Supply |
12–30 VDC |
| Sensitivity |
High sensitivity for minimal vibration detection |
| Frequency Range |
Wide range suitable for various machinery |
| Design |
Compact, robust for installation in confined spaces |
| Compatibility |
Supports integration with multiple monitoring systems |
| Power Consumption |
Low, energy-efficient operation |
| Weight |
0.5 Kg |
Model Code Explanation
The 177230-01-01-05 model follows Bently Nevada’s standard naming convention:
-
177230 – Base part number representing the seismic transmitter family.
-
-01 – Denotes a specific hardware revision optimized for industrial vibration sensing.
-
-01 – Secondary variant code indicating factory configuration or signal conditioning setup.
-
-05 – Final suffix identifies firmware version, calibration set, or regional specification.
This full code ensures correct identification for replacement, ordering, and integration into existing monitoring systems.
Installation Recommendations and Wiring Guidance
For reliable operation, mount the 177230-01-01-05 Seismic Transmitter on a stable surface near the monitored machinery. Avoid excessive vibration and ensure environmental protection within IP65 limits.
Use shielded cables for all signal connections to minimize electromagnetic interference. The 4–20 mA output should connect to compatible monitoring or data acquisition systems. Verify polarity and power supply voltage (12–30 VDC) before energizing the unit. Proper grounding is essential to ensure signal accuracy and prevent measurement noise.
During commissioning, confirm sensor response, signal linearity, and integration with the monitoring platform. Secure all connectors and perform functional testing to validate alarms and data acquisition.
Frequently Asked Questions
Which equipment can this transmitter monitor?
It is suitable for turbines, pumps, compressors, motors, and other rotating machinery.
What type of output signal does it provide?
The transmitter outputs a standard 4–20 mA signal compatible with most industrial monitoring systems.
Is it suitable for harsh environments?
Yes. Its IP65 rating and wide operating temperature range (-40°C to 85°C) ensure reliable performance in industrial conditions.
Can it detect minimal vibrations?
Yes, the high sensitivity allows early detection of even subtle mechanical anomalies.
Does it require calibration before installation?
Factory calibration is provided, but verification during commissioning is recommended to ensure optimal system integration.